Indoor telecommunication & Fire alarm cables
J-Y(St)Y Lg
02.09.02
|
Use of Cable
installation cable with electrostatic shield for telecommunication and IT-systems for lossless transmission of datas and signals. Suitable for fixed laying in dry and humid rooms, on-wall and in-wall, outdoor use, no laying underground.
Product information "J-Y(St)Y Lg"
Special features
- shielded by plastic-clad aluminium foil
- pairs stranded in layers (Lg)
- largely resistant to acids, bases and usual oils
- free from lacquer damaging substances and silicone (during production)
- also available: JYY Bd. or J-Y(St)Y Lg BMK n x 2 x 0,8 mm as fire alarm cable with red outer sheath
- conform to RoHS
- conform to 2006/95/EC-Guideline CE.
- installation cables are not designed for high voltage purposes and are not suitable for laying underground
- We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: | Copper conductor blank |
---|---|
Conductor class: | Conductor-Ø 0,6 mm (0,28 mm²), conductor-Ø 0,8 mm (0,50 mm²) |
Core insulation: | PVC |
Core identification: | Acc. to DIN VDE 0815 different colours |
Stranding: | Pairs stranded in layers (2-pair-cable also possible as star quad) |
Shield3: | Plastic-clad aluminium foil with subjacent drain wire |
Outer sheath: | PVC |
Sheath colour: | Grey, RAL 7032 (fire alarm cable: red) |
Rated voltage: | 300 V |
Testing voltage: | 800 V |
Conductor resistance: | Loop: 0,6 max. 130 Ω / km; 0,8 max. 73,2 Ω / km |
Insulation resistance: | Min. 100 MΩ x km |
Current-carrying-capacity: | Acc. to DIN VDE, s. Techn. Guidelines |
Capacity: | Max. 100 nF/km |
Min. bending radius fixed: | 7,5 x d |
Min. bending radius moved: | 10 x d |
Operat. temp. fixed min/max: | -30 °C / +70 °C |
Operat. temp. moved min/max: | - 5 °C / +50 °C |
Burning behavior: | Self-extinguishing & flame-retardant acc.to IEC 60332-1 |
Standard: | Acc. to DIN VDE 0815 |
There aren't any asked questions yet.
A-2Y(L)2Y St III Bd , A-2YF(L)2Y St III Bd
02.09.05
Outdoor telecommunication cables
VDE0816, 300V, shielded, UV-resistant
VDE0816, 300V, shielded, UV-resistant
Item count
59
J-Y(St)Y Lg
02.09.02
Indoor telecommunication & Fire alarm cables
VDE0815, 300V, shielded, CPR Eca
VDE0815, 300V, shielded, CPR Eca
Item count
57
J-H(ST)H Bd
02.09.04
Indoor telecommunication & Fire alarm cables
VDE0815, 300V, shielded, halogen free, different CPR versions available
VDE0815, 300V, shielded, halogen free, different CPR versions available
Item count
33