A-2Y(L)2Y ST III BD 60X2X0,8 - BLACK RAL 9005 | M0006000_2002988
Outdoor telecommunication cables

A-2Y(L)2Y St III Bd , A-2YF(L)2Y St III Bd

02.09.05

|

Application
outdoor telephone cable for railway station telecommunication, in business and industrial facilities, in telecommunication and IT-systems for lossless transmission of datas and signals. Suitable for fixed laying in dry and humid rooms, on-wall and in-wall, outdoor use and laying underground.
Selected item
Item no.: Description:
2002988 A-2Y(L)2Y ST III BD 60X2X0,8 BLACK RAL 9005
Variants
Item no. Dimension Outer-Ø [mm] nom. Cu Index [kg/km] Weight [kg/1.000]
"A-2Y(L)2Y St III Bd , A-2YF(L)2Y St III Bd "
SPECIAL FEATURES
  • shielded by plastic coated aluminium tape
  • quads stranded in bundles (St III Bd) with PE-outer sheath in layers
  • largely resistant to acids, bases, saline solution, water, alcohol, oil and petrol
  • free from lacquer damaging substances and silicone (during production)
  • A-2Y(L)2Y St III Bd: radially watertight, A-2YF(L)2Y St III Bd: radially & longitudinally watertight
  • UV-resistant outer sheath
REMARKS
  • RoHS compliant
  • conforms to the 2006/95/EC Directive ("Low Voltage Directive") CE.
  • Special versions, other dimensions, cross-sections, wire and sheath colors are available on request.
DESIGN
Conductor material copper conductor blank
Conductor class conductor-Ø 0,6 mm (0,28 mm²), conductor-Ø 0,8 mm (0,5 mm²)
Core insulation PE
Core identification acc. to VDE 0816: basic colours with black printed rings
Stranding cores stranded to star-quads, bundles stranded in layers; A-2YF(L)2Y St III Bd: hollow spaces of cable strand filled with jelly filling
Overall shield double-sided plastic coated aluminium tape
Outer sheath material PE
Sheath colour black
ELECTRICAL PROPERTIES
Rated voltage AC IEC 225 V
Testing voltage core/core: 500 V; core/shield: 2 kV
Conductor resistance loop: 0,6 max. 130 Ω / km ; 0,8 max 73,2 Ω / km
Insulation resistance min. 5 GΩ x km
Current carrying capacity acc. to DIN VDE, s. Techn. Guidelines
Capacity max. 52 nF/km
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed 7,5 x d
Min. bending radius moved 10 x d
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C] +70 °C
Operat. temp. moved min/max [°C] -20 °C / +50 °C

Please enter a valid email address.
Please enter a valid question.
Fields marked with * are mandatory.
KAWEFLEX® Allround 7110 SK-PVC UL/CSA 04.11.05
Control cables for use in drag chains
for increased requirements, 300/500V, unshielded, UL/CSA
Item count 47
KAWEFLEX® Allround 7720 SK-TP-C-PUR UL/CSA 04.15.10
Electronic cables for use in drag chains
for high requirements, 300V, shielded, halogen-free, UL/CSA
Item count 24
NYCY 0,6/1kV 09.07.02
Power Cables
0,6/1kV, shielded, UV-resistant, direct burial, VDE, CPR Eca
Item count 47
SiD, SiD/GL, SiF, SiF/GL, SiFF, SiFv, SiZ 08.04.01
Silicone insulated cables up to +180°C
300/500V, singles cores & twin cable, halogen-free, solid & fine stranded,
GL:glass silk braid
Item count 273