Indoor Outdoor
UV-resistant Oil resistant
CE
fixed installation flexible use continuously dynamic, high flexible use Drag chain Festoon Reeling
Reelable cables

REELTEC® KSM-S (N)SHTÖU, (N)SHTÖU+LWL

06.09.16.01

|

Application

reeling cable for winding operation, especially with simultaneously tensile stress and/or torsional stress and/or forced cable guidance. Suitable for dry, humid and wet rooms, for outdoor use and also on construction sites, in commercial and agricultural plants.

Selected item
Item no.: Description:
3004410 REELTEC KSM-S (N)SHTÖU-J + FO 3X35+2G16/2+12G62,5/125 0,6/1 KV, REELING CABLE
Variants
Filter
There are currently no available alternative products.
PRODUCT INFO "REELTEC® KSM-S (N)SHTÖU, (N)SHTÖU+LWL "
SPECIAL FEATURES
  • free from lacquer damaging substances and silicone (during production)
  • for travelling speed up to 180 m / min
  • where excessive stress, particularly high dynamic tensile force may be expected, e. g. as a result of high acceleration figures, the permissible stress limits have to be determinated individually.
  • failure-free data transmission via FO
REMARKS
  • RoHS compliant
  • Compliant with the 2014/35/EU Directive (''Low Voltage Directive'') CE
  • Special versions, other dimensions, cross-sections, core and sheath colors are available on request
  • Also available assembled with terminations and ST connectors (fiber optic)
PRODUCT DETAILS
DESIGN
Conductor material bare copper strand; FO: Graded index-fibre 62,5/125 µ
Conductor class acc. to DIN VDE 0295 class 5 resp. IEC 60228 cl. 5
Core insulation rubber compound; FO: with jelly filled PETP tubes in an envelope of a special rubber compound
Core identification acc. to VDE 0293-308 coloured and GNYE
Overall stranding cores stranded in layer, splitted earth conductors and FO element in the interstices
Inner sheath material special rubber-compound
Anti-torsion braid wide-meshed polyester braid
Outer sheath material special rubber-compound
Sheath colour black
ELECTRICAL PROPERTIES
Rated voltage AC IEC Uo/U: 0,6/1 kV
Testing voltage 2,5 kV
Current carrying capacity acc. to DIN VDE, see Technical Guideline
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed acc. to DIN VDE 0298 part 3
Min. bending radius moved acc. to DIN VDE 0298 part 3
Traverse speed (m/s) - festoon max. 3 m / s
Traverse speed (m/s) - reeling max. 3 m / s
Tensile strength max. 20 N / mm²
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C] -40 °C / +80 °C
Operat. temp. moved min/max [°C] -40 °C / +80 °C
Temp. at conductor in operation max [°C] +90 °C