Indoor
Shielded Oil resistant
CE CPR Class - Eca
fixed installation flexible use
Electronic and control cables for intrinsically safe circuits

PAARTRONIC®-CY LIYCY (TP) EB

02.03.06

|

Application

exclusively for use in self-protective circuits, as impulse and data transmission cable, control and connecting cable in process controlled facilities in measurement and control technology for lossless data and signal transmission. For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only with UV-protection, no laying underground.

Selected item
Item no.: Description:
0501195 PAARTRONIC-CY EB LIYCY (TP) 4X2X0,75 DIN47100, BLUE RAL 5015
Variants
Filter
TKD SmartFit+ automatically finds technically equivalent or better alternatives to a searched product. Performance, quality, and compatibility are taken into account—for cases in which the highest requirements must be met or exceeded.
Filter

Filter according to your requirements.

fixed installation flexible use
PAARTRONIC®-CY LIYCY (TP) 4 X 2 X 1 0501196
Electronic cables
DIN47100, 250V, twisted pairs, shielded, CPR Eca
7/10
We recommend this product as a suitable alternative!
fixed installation flexible use
ELITRONIC®-CY LIYCY 8 X 0,75 0500659
Electronic cables
DIN47100, 250V, shielded, CPR Eca
UN/ECE-R 118.02
5/10
We recommend this product as a suitable alternative!
TKD CoreFit offers functional alternatives that cover the core benefits of the original product—often with reduced functionality or simpler design, but at a lower price.
Filter

Filter according to your requirements.

fixed installation
J-Y(St)Y Lg 4 X 2 X 0,6 2000194
Indoor telecommunication & Fire alarm cables
VDE0815, 300V, shielded, CPR Eca
We recommend this product as a suitable alternative!
fixed installation
A-2Y(L)2Y St III Bd , A-2YF(L)2Y St III Bd 4 X 2 X 0,6 2003334
Outdoor telecommunication cables
VDE0816, 300V, shielded, UV-resistant
We recommend this product as a suitable alternative!
fixed installation
A-2Y(L)2Y St III Bd , A-2YF(L)2Y St III Bd 4 X 2 X 0,6 2000029
Outdoor telecommunication cables
VDE0816, 300V, shielded, UV-resistant
We recommend this product as a suitable alternative!
fixed installation
INDULINE® RE-2X(ST)YSWAY-FL 4 X 2 X 0,75 2001357
Instrumentation cables
300V, shielded, +90C, steel wire armour, EN50288-7, CPR Eca
We recommend this product as a suitable alternative!
fixed installation
INDULINE® RE-2X(ST)YSWAY-FL PIMF 4 X 2 X 0,75 2001397
Instrumentation cables
300V, shielded, +90C, pairs in metal foil, steel wire armour
EN50288-7, CPR Eca
We recommend this product as a suitable alternative!
Despite careful pre-evaluation of our alternatives, we ask you to review the selection based on your requirements. Our recommendations include at least equivalent, and in some cases better, properties.
PRODUCT INFO "PAARTRONIC®-CY LIYCY (TP) EB "
SPECIAL FEATURES
  • twisted pairs
  • for intrinsically safe electric circuits
  • protection class "i" acc. to VDE 0165
  • largely resistant to acids, bases and specified types of oil
  • intrinsically safe systems are circuits where no spark and no thermic effect in normal operation or in failure can ignite explosive surrounding areas. These products are intended for use within <50 V AC resp. <75 V DC voltage. Therefore they are not subject to the EU Low Voltage Directive.
REMARKS
  • RoHS-compliant
  • LBS-free/silicon-free (during production)
  • Recommended for EMC-compliant application
  • Alternatively available: ÖPVC-JZ-YCY EB, ELITRONIC®-CY EB (DIN47100)
PRODUCT DETAILS
DESIGN
Conductor material bare copper strand
Conductor class acc. to IEC 60228 cl. 5
Core insulation PVC
Core identification acc. to DIN 47100 different colours
Stranding 2 cores twisted to a pair, pairs stranded in layers
Protection against contact polyester foil
Overall shield copper braid tinned; coverage approx. 85%
Outer sheath material PVC
Sheath colour blue, RAL 5015
ELECTRICAL PROPERTIES
Rated voltage AC IEC Uo/U: 300/500 V (see special features)
Testing voltage core/core: 1,5 kV; core/shield: 2 kV
Conductor resistance acc. to IEC 60228 cl. 5
Insulation resistance min. 20 MΩ x km
Current carrying capacity acc. to DIN VDE, s. Techn. Guidelines
Capacity core/core ca. 120 nF/km; core/shield ca. 160 nF/km
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed up to 12 mm Ø 5 x d; > 12 mm Ø 7,5 x d
Min. bending radius moved up to 12 mm Ø 10 x d; up to 20 mm Ø 15 x d; > 20 mm Ø 20 x d
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C] -30 °C / +80 °C
Operat. temp. moved min/max [°C] -5 °C / +70 °C