Electronic and control cables for intrinsically safe circuits
PAARTRONIC®-CY LIYCY (TP) EB
02.03.06
|
exclusively for use in self-protective circuits, as impulse and data transmission cable, control and connecting cable in process controlled facilities in measurement and control technology for lossless data and signal transmission. For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only with UV-protection, no laying underground.
Filter according to your requirements.
Electronic and control cables for intrinsically safe circuits
Properties
| Number of cores | 8 |
|---|---|
| Outer sheath material | PVC |
| Cross section | 0,75 |
Electronic cables
Properties*
| Number of cores | 8 |
|---|---|
| Outer sheath material | PVC |
| Cross section | 1 |
Electronic cables
Properties*
| Number of cores | 8 |
|---|---|
| Outer sheath material | PVC |
| Cross section | 0,75 |
Filter according to your requirements.
Indoor telecommunication & Fire alarm cables
Outdoor telecommunication cables
Outdoor telecommunication cables
Instrumentation cables
SPECIAL FEATURES
- twisted pairs
- for intrinsically safe electric circuits
- protection class "i" acc. to VDE 0165
- largely resistant to acids, bases and specified types of oil
- intrinsically safe systems are circuits where no spark and no thermic effect in normal operation or in failure can ignite explosive surrounding areas. These products are intended for use within <50 V AC resp. <75 V DC voltage. Therefore they are not subject to the EU Low Voltage Directive.
REMARKS
- RoHS-compliant
- LBS-free/silicon-free (during production)
- Recommended for EMC-compliant application
- Alternatively available: ÖPVC-JZ-YCY EB, ELITRONIC®-CY EB (DIN47100)
PRODUCT DETAILS
DESIGN
| Conductor material | bare copper strand |
|---|---|
| Conductor class | acc. to IEC 60228 cl. 5 |
| Core insulation | PVC |
| Core identification | acc. to DIN 47100 different colours |
| Stranding | 2 cores twisted to a pair, pairs stranded in layers |
| Protection against contact | polyester foil |
| Overall shield | copper braid tinned; coverage approx. 85% |
| Outer sheath material | PVC |
| Sheath colour | blue, RAL 5015 |
ELECTRICAL PROPERTIES
| Rated voltage AC IEC | Uo/U: 300/500 V (see special features) |
|---|---|
| Testing voltage | core/core: 1,5 kV; core/shield: 2 kV |
| Conductor resistance | acc. to IEC 60228 cl. 5 |
| Insulation resistance | min. 20 MΩ x km |
| Current carrying capacity | acc. to DIN VDE, s. Techn. Guidelines |
| Capacity | core/core ca. 120 nF/km; core/shield ca. 160 nF/km |
MECHANICAL & DYNAMIC PROPERTIES
| Min. bending radius fixed | up to 12 mm Ø 5 x d; > 12 mm Ø 7,5 x d |
|---|---|
| Min. bending radius moved | up to 12 mm Ø 10 x d; up to 20 mm Ø 15 x d; > 20 mm Ø 20 x d |
THERMAL PROPERTIES
| Operat. temp. fixed min./max. [°C] | -30 °C / +80 °C |
|---|---|
| Operat. temp. moved min/max [°C] | -5 °C / +70 °C |