BUS | FIELDBUS cables for industrial & process automation
MULTIBUS & INTERBUS 100 - 120 Ohm - HF UL/CSA -high flexible -
03.10.02.02
|
MULTIBUS - as fieldbus cable for use in a variety of fieldbus systems such as DIN measuring bus, BITBUS (IEEE 1118), Local Operating Network (LON) SUCOnet P, Modulink-P, P-VariNet, FIP ... and INTERBUS - as remote bus cable (Type RBC) or installation remote bus with integrated power supply (type INBC) in the field of production automation, for high flexible applications (e.g. power chains, gantry robots, pick and place units, conveyors, machine tools, automated production systems, etc.)
SPECIAL FEATURES
- low adhesion
- largely resistant to lubricants, coolants fluids and grease
- oil-resistant: acc. to DIN EN 60811-2-1
- UV-resistant
- EMC compliant shielding
- max. cable lengths for a bus segment acc.to PI at stated transmission rate: MULTIBUS: 93,75kbit/s-max.1,2km | 187,5kbit/s-max.1km | 0,5Mbit/s-max.400m 1,5 Mbit/s-max.200m | 12,0 Mbit/s-max.100m INTERBUS: 0,5Mbit/s-max.400m
REMARKS
- RoHS-compliant
- DESINA-compliant (violet)
- Compliant with the 2014/35/EU Directive (''Low Voltage Directive'') CE
- LABS/silicone-free (during production)
- FRNC: Flame Retardant Non Corrosive, halogen-free
PRODUCT DETAILS
DESIGN
| Conductor material | bare copper strand |
|---|---|
| Conductor class | super fine wired acc. to IEC 60228 cl. 6 |
| Core insulation | BUScores: Polyolefine, supply cores: PVC |
| Core identification | BUScores: acc. to DIN 47100, supply cores: rd, bu, gnye |
| Stranding | BUScores stranded to a pair |
| Overall stranding | (INBC) BUSelem. a. supply cores stranded |
| Overall shield | copper braid tinned |
| Outer sheath material | PUR |
| Sheath colour | violet RAL 4001 (VT) |
ELECTRICAL PROPERTIES
| Rated voltage AC IEC | BUScores: 250 V (not for high voltage purposee); supply cores: 500 V |
|---|---|
| Testing voltage | 1,5 kV |
| Loop resistance | max. 159,8 Ω/km - 0,25 mm²: max. 39,0 Ω/km 1,0 mm² |
| Capacity | max. 60 nF/km |
| Characteristic impedance | MULTIBUS: 100 - 120 Ω; INTERBUS: 100 Ω +/- 15 Ω |
MECHANICAL & DYNAMIC PROPERTIES
| Min. bending radius fixed | 5 x d |
|---|---|
| Min. bending radius moved | 7,5 x d < 3mTL* | 15 x d ≥ 3mTL*, |
| Traverse length (m) - drag chain | max. 10 m |
| Traverse speed (m/s) - drag chain | self-supporting: 4 m/s |
| Acceleration (m/s²) - drag chain | max. 5 m/s² |
THERMAL PROPERTIES
| Operat. temp. fixed min./max. [°C] | - 40 °C / +80 °C |
|---|---|
| Operat. temp. moved min/max [°C] | - 30 °C / +70 °C |
PROPERTIES IN CASE OF FIRE
| Halogen-free | acc. to IEC 60754-1 (FRNC Typen) |
|---|---|
| Burning behavior | flame retardant acc. to IEC 60332-1-2; CMX: acc. to IEC 60332-1-2, VW-1 |