Cables for servo-drives
KAWEFLEX® SERVO 9YSL(St)CY... VFD UL/CSA 0,6/1 kV EMV
05.01.34
|
power, control and connecting cable for drive systems with frequency converter technology, for fixed laying and casually movement without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet rooms.
Versions with black outer sheath (DB - direct burial) are additionally suitable for outdoor use and for direct burial.
SPECIAL FEATURES
- largely resistant to acids, bases and specified types of oil
- max. perm. current carrying capacity at 30 °C ambient temperature
- low operating capacity, low coupling resistance
- black version: UV-resistant, cold flexible, outdoor and direct burial use PVC outer jacket
- enables trouble-free operation of frequency converters through optimum EMC compliant shielding
- low capacitance enables longer cable lengths between motor and frequency converter
REMARKS
- RoHS-compliant, compliant with the 2014/35/EU Directive (''Low Voltage Directive'') CE
- LABS/silicon-free (during production)
- Outdoor use and direct installation in the ground are not included in the UL/CSA scope of approval.
- Special designs are available on request.
PRODUCT DETAILS
DESIGN
| Conductor material | bare copper strand |
|---|---|
| Conductor class | acc. to IEC 60228 cl. 5 |
| Core insulation | PP |
| Core identification | acc. to DIN VDE 0293-308 coloured cores with GNYE |
| Stranding | 4-core version: cores stranded in one layer | 3+3-core version: cores stranded concentrically, protective conductor divided into three, positioned in the crotches |
| Overall shield | alu-lamin. polyester foil, metal side outside, cover. 100% under copper braid tinned |
| Outer sheath material | PVC |
| Sheath colour | transparent, DB-version: black |
ELECTRICAL PROPERTIES
| Rated voltage AC IEC | acc. to IEC: 0,6/1 kV, acc. to UL: 1.000 V - highest permissible operating voltage Single phase and three-phase: 700/1200 V, DC operation: 900/1800 V |
|---|---|
| Testing voltage | 4 kV |
| Conductor resistance | acc. to IEC 60228 cl. 5 |
| Insulation resistance | min. 200 MΩ x km |
| Current carrying capacity | look at the table on the right side |
| Capacity | look at the table on the right side |
MECHANICAL & DYNAMIC PROPERTIES
| Min. bending radius fixed | 4 x d |
|---|---|
| Min. bending radius moved | 15 x d |
THERMAL PROPERTIES
| Operat. temp. fixed min./max. [°C] | transparent: -40°C / +80°C; black: IEC: -40°C / +90°C, UL/CSA: -40°C / +80°C |
|---|---|
| Operat. temp. moved min/max [°C] | transparent: - 5°C / +80°C; black: IEC: - 5°C / +90°C, UL/CSA: - 5°C / +80°C |
| Temp. at conductor in operation max [°C] | + 90 °C in operation; +250 °C in case of short-circuit |