Use of Cable
increased oil-resistant control and power supply cables for use in cable trays or cable channels with frequency converter technology. For medium mechnical stresses,for fixed or flexible installation where free movement is required without tensile stress and without forced guidance systems, in dry, damp and wet interiors (incl. water-oil mixtures). For outdoor use and also for direct burial. TC-ER (Tray Cable - Exposed Run) approval open wiring between cable tray and industrial machines/plants acc. NEC 336.10(7)
Product information "KAWEFLEX® SERVO 2XSL(St)CYK... VFD TRAY UL/CSA 0,6/1 kV EMC"
Special features
- increased resistance to oil by special PVC outer sheath, largely resistant to acids and bases
- max. perm. current carrying capacity at 30 ° C ambient temp.
- direct burial
- UV-res.acc.to EN 50396 & HD 605 A1; SUN RES acc.to UL 1581
- low operating capacity, low coupling resistance
- flexible at low temperatures up to -15 °C
- TC-ER (Tray Cable - Exposed Run)
- enables trouble-free operation of frequency converters through optimum EMC compliant shielding
- conform to RoHS, conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- LABS-/silicone-free (during production)
- conform to NFPA 79 2007 wiring norms and NEC 336.10 (7) acc. to NEC "National Electric Code"
- Special versions, other dimensions, cross-sections, core and jacket colours are manufactured on request.
Conductor material: | Bare copper strand |
---|---|
Conductor class: | Acc. to IEC 60228 cl. 5 |
Core insulation: | XLPE |
Core identification: | Acc. to DIN VDE 0293-308 coloured cores with GNYE |
Stranding: | Stranded in layers |
Shield3: | Alu-lamin. polyester foil, metal side outside, cover. 100% under copper braid tinned |
Outer sheath: | PVC |
Sheath colour: | Black, RAL 9005 |
Rated voltage: | Uo/U 0,6/1 kV (UL 1277: 600 V) - highest permissible operating voltage Single phase and three-phase: 700/1200 V, DC operation: 900/1800 V |
Testing voltage: | 6 kV |
Conductor resistance: | Acc. to IEC 60228 cl. 5 |
Insulation resistance: | Min. 200 MΩ x km |
Current-carrying-capacity: | Look at the table on the right side |
Capacity: | Siehe Tabelle rechte Seite |
Min. bending radius fixed: | ≤ 12mm Ø: 5 x d; ≤ 20mm Ø: 7,5 x d; > 20mm Ø: 10 x d |
Min. bending radius moved: | ≤ 12mm Ø: 10 x d; ≤ 20mm Ø: 15 x d; > 20mm Ø: 20 x d |
Operat. temp. fixed min/max: | -40 °C / +90 °C |
Operat. temp. moved min/max: | -15 °C / +80 °C |
Temp. at conductor: | + 90 °C in operation; +250 °C in case of short-circuit |
Burning behavior: | Self-extinguishing & flame-retardant acc.to IEC 60332-3-24 Cat. C, FT4/IEEE |
Resistant to oil: | UL OIL RES I |
Approvals: | UL/CSA: cULus 600 V / 90 °C - UL1277 |
There aren't any asked questions yet.
KAWEFLEX® SERVO 2XSL(St)CY... & 2XSL(St)CYK... 0,6/1 kV EMC
05.01.32
Cables for servo-drives
0,6/1kV, EMC optimized, double shielded, K: cold flexible, UV-resistant
0,6/1kV, EMC optimized, double shielded, K: cold flexible, UV-resistant
Item count
45
KAWEFLEX® SERVO 9YSL(St)CY... VFD UL/CSA 0,6/1 kV EMC
05.01.34
Cables for servo-drives
0,6/1kV, EMC optimized, double shielded, BK: UV-resistant, direkt burial, UL/CSA, CPR Eca
0,6/1kV, EMC optimized, double shielded, BK: UV-resistant, direkt burial, UL/CSA, CPR Eca
Item count
30
KAWEFLEX® SERVO 2XSL(St)CYK... VFD TRAY UL/CSA 0,6/1 kV EMC
05.01.36
Cables for servo-drives
0,6/1kV, EMC optimized, double shielded, K: cold flexible, UV-resistant, direkt burial, UL/CSA, CPR Eca
0,6/1kV, EMC optimized, double shielded, K: cold flexible, UV-resistant, direkt burial, UL/CSA, CPR Eca
Item count
23
KAWEFLEX® SERVO 2XSL(St)CHK... FRNC 0,6/1kV EMC
05.01.38
Cables for servo-drives
0,6/1kV, EMC optimized, double shielded , halogen-free, K: cold flexible, UV-resistant, CPR Cca
0,6/1kV, EMC optimized, double shielded , halogen-free, K: cold flexible, UV-resistant, CPR Cca
Item count
30