KAWEFLEX 6530 SK-TP-C-PUR UL/CSA 8X2X0,14 (AWG26) - DIN 47100, GREY RAL 7001 | M0006761_1505006
Indoor Outdoor
Shielded UV-resistant Oil resistant Halogen-free
CE CSA
fixed installation flexible use continuously dynamic, high flexible use Drag chain
Electronic cables for use in drag chains

KAWEFLEX® 6530 SK-TP-C-PUR UL/CSA

04.10.30

|

Application
twisted pair shielded electronic cable for data and signal transmission for high electrical and mechanical requirements in drag chains, in electrical motion facilities, machine tools and handling automats.
Selected item
Item no.: Description:
1505006 KAWEFLEX 6530 SK-TP-C-PUR UL/CSA 8X2X0,14 (AWG26) DIN 47100, GREY RAL 7001
Variants
Filter
There are currently no available alternative products.
PRODUCT INFO "KAWEFLEX® 6530 SK-TP-C-PUR UL/CSA "
SPECIAL FEATURES
  • UL/CSA approved
  • low adhesion, silicone-free
  • UV-resistant
  • halogen free, flame-retardant acc. to IEC 60332-1-2, FT1, VW1
  • oilresistant acc. to DIN EN 60811-404
  • largely resistant to grease, coolant fluids and lubricants
  • recommended for EMC-compatible applications
REMARKS
  • RoHS compliant
  • Compliant with the 2014/35/EU Directive ("Low Voltage Directive") CE
  • Special versions, other dimensions, cross-sections, wire and sheath colors are available on request.
PRODUCT DETAILS
DESIGN
Conductor material bare copper strand
Conductor class super fine wires acc.to VDE 0295 cl. 6 pt. 4 resp. IEC60228 cl. 6 pt. 4
Core insulation PELON®2
Core identification coloured acc. to DIN 47100
Overall stranding cores twisted to pairs, pairs stranded in layers
Overall shield copper braid tinned, coverage approx. 85% ± 5%
Outer sheath material PUR
Sheath colour grey RAL 7001
ELECTRICAL PROPERTIES
Rated voltage AC IEC acc. to VDE: 300/300V; acc. to UL: 300 V
Testing voltage core/core: 1.500 V; core/shield: 500 V
Conductor resistance at +20 °C acc. to DIN VDE 0295 cl.6 resp. IEC60228 cl.6
Insulation resistance at +20 °C ≥ 500 MΩ x km
Current carrying capacity acc. to DIN VDE
Capacity core/core: approx. 65 pF/m
Inductivity approx. 0,6 mH/km
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed 5 x d
Min. bending radius moved 7,5 x d < 10 m TL; 10 x d ≥ 10 m TL
Traverse length (m) - drag chain max. 50 m
Traverse speed (m/s) - drag chain self-supporting: max. 10 m/s, gliding: max. 5 m/s
Acceleration (m/s²) - drag chain max. 20 m/s²
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C] -50 °C / +80 °C
Operat. temp. moved min/max [°C] -40 °C / +80 °C