Control cables for use in drag chains
KAWEFLEX® 6130 SK-PUR UL/CSA
04.09.15
|
as highly flexible, low capacity power and control cable for high electrical and mechanical requirements in drag chains and motion drive systems in machine and plant engineering.
Control cables for use in drag chains
Control cables for use in drag chains
Control cables for use in drag chains
Control cables for use in drag chains
Control cables for use in drag chains
Control cables for use in drag chains
SPECIAL FEATURES
- UL/CSA approved, conform to DESINA
- low adhesion, silicone-free
- UV-resistant
- halogen free, flame-retardant acc. to IEC 60332-1-2, FT1
- oilresistant acc. to DIN EN 60811-404
- largely resistant to grease, coolant fluids and lubricants
- due to 1.000 V UL/CSA approval parallel laying with other 1.000 V cables is permitted
REMARKS
- compliant with RoHS and 2014/35/EU Directive ("Low Voltage Directive") CE
- Special versions, other dimensions, cross-sections, wire and sheath colors are available on request.
- NEW: with reduced outer diameters, for lighter construction, smaller bending radii and lower weight; from production date January 2020
PRODUCT DETAILS
DESIGN
| Conductor material | bare copper strand |
|---|---|
| Conductor class | acc. to DIN VDE 0295 class 6 pt. 4 resp. IEC 60228 cl. 6 pt. 4 |
| Core insulation | PELON®2 |
| Core identification | acc. to DIN VDE 0293 black wires with white numerals, 1 x GNYE |
| Overall stranding | cores stranded in layers |
| Outer sheath material | PUR |
| Sheath colour | grey RAL 7001 |
ELECTRICAL PROPERTIES
| Rated voltage AC IEC | acc. to IEC: 600/1.000V | acc. to UL: 1.000 V |
|---|---|
| Testing voltage | 4 kV |
| Conductor resistance | at +20 °C acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6 |
| Insulation resistance | at +20 °C ≥ 20 MΩ x km |
| Current carrying capacity | acc. to DIN VDE |
MECHANICAL & DYNAMIC PROPERTIES
| Min. bending radius fixed | 4 x d |
|---|---|
| Min. bending radius moved | 7,5 x d < 10 m TL | 10 x d ≥ 10 m TL |
| Traverse length (m) - drag chain | max. 50 m |
| Traverse speed (m/s) - drag chain | self-supporting: max. 10 m/s, gliding: max. 5 m/s |
| Acceleration (m/s²) - drag chain | max. 20 m/s² |
THERMAL PROPERTIES
| Operat. temp. fixed min./max. [°C] | -50 °C / +80 °C |
|---|---|
| Operat. temp. moved min/max [°C] | -40 °C / +80 °C |
PROPERTIES IN CASE OF FIRE
| Halogen-free | halogen-free acc. to IEC 60754-1 |
|---|---|
| Burning behavior | flame-retardant acc. to IEC 60332-1-2, FT1 |