J-Y(ST)Y LG 2X2X0,8 - GREY RAL 7032 | M0005904_2000187
Indoor
Shielded Oil resistant
CE CPR Class - Eca
fixed installation
Indoor telecommunication & Fire alarm cables

J-Y(St)Y Lg

02.09.02

|

Application

installation cable with electrostatic shield for telecommunication and IT-systems for lossless transmission of datas and signals. Suitable for fixed laying in dry and humid rooms, on-wall and in-wall, outdoor use, no laying underground.

Selected item
Item no.: Description:
2000187 J-Y(ST)Y LG 2X2X0,8 GREY RAL 7032
Variants
Filter
TKD SmartFit+ automatically finds technically equivalent or better alternatives to a searched product. Performance, quality, and compatibility are taken into account—for cases in which the highest requirements must be met or exceeded.
Filter

Filter according to your requirements.

fixed installation
Currently selected
J-Y(St)Y Lg 2 X 2 X 0,8 2000187
Indoor telecommunication & Fire alarm cables
VDE0815, 300V, shielded, CPR Eca

Properties
Number of cores 4
Outer sheath material PVC
Cross section 0,8
10/10
fixed installation flexible use
ELITRONIC®-OZ-CY LIYCY-OZ EB 4 X 1 0500818
Electronic and control cables for intrinsically safe circuits
300/500V, shielded, blue

Properties*
Number of cores 4
Outer sheath material PVC
Cross section 1
2/10
TKD CoreFit offers functional alternatives that cover the core benefits of the original product—often with reduced functionality or simpler design, but at a lower price.
Filter

Filter according to your requirements.

fixed installation
INDULINE® RE-2X(ST)YSWBY-FL 2 X 2 X 0,75 2001276
Instrumentation cables
300V, shielded, +90C, steel wire braid, EN50288-7, CPR Eca
fixed installation
INDULINE® RE-2X(ST)YSWAY-FL 2 X 2 X 0,75 2001356
Instrumentation cables
300V, shielded, +90C, steel wire armour, EN50288-7, CPR Eca
fixed installation
INDULINE® RE-2X(ST)YSWAY-FL PIMF 2 X 2 X 0,75 2001396
Instrumentation cables
300V, shielded, +90C, pairs in metal foil, steel wire armour
EN50288-7, CPR Eca
fixed installation
INDULINE® RE-2X(ST)YSWAY-FL 2 X 2 X 0,75 2001355
Instrumentation cables
300V, shielded, +90C, steel wire armour, EN50288-7, CPR Eca
Despite careful pre-evaluation of our alternatives, we ask you to review the selection based on your requirements. Our recommendations include at least equivalent, and in some cases better, properties.
PRODUCT INFO "J-Y(St)Y Lg "
SPECIAL FEATURES
  • shielded by plastic-clad aluminium foil
  • pairs stranded in layers (Lg)
  • largely resistant to acids, bases and usual oils
  • free from lacquer damaging substances and silicone (during production)
  • also available: JYY Bd. or J-Y(St)Y Lg BMK n x 2 x 0,8 mm as fire alarm cable with red outer sheath
REMARKS
  • RoHS compliant
  • compliant with the 2006/95/EC Directive ("Low Voltage Directive") CE.
  • Installation cables are not suitable for heavy current installation purposes and for underground installation
  • Special versions, other dimensions, cross-sections, core and sheath colors are available on request.
PRODUCT DETAILS
DESIGN
Conductor material copper conductor blank
Conductor class conductor-Ø 0,6 mm (0,28 mm²), conductor-Ø 0,8 mm (0,50 mm²)
Core insulation PVC
Core identification acc. to DIN VDE 0815 different colours
Stranding pairs stranded in layers (2-pair-cable also possible as star quad)
Overall shield plastic-clad aluminium foil with subjacent drain wire
Outer sheath material PVC
Sheath colour grey, RAL 7032 (fire alarm cable: red)
ELECTRICAL PROPERTIES
Rated voltage AC IEC 300 V
Testing voltage 800 V
Conductor resistance loop: 0,6 max. 130 Ω / km; 0,8 max. 73,2 Ω / km
Insulation resistance min. 100 MΩ x km
Current carrying capacity acc. to DIN VDE, s. Techn. Guidelines
Capacity max. 100 nF/km
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed 7,5 x d
Min. bending radius moved 10 x d
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C] -30 °C / +70 °C
Operat. temp. moved min/max [°C] - 5 °C / +50 °C