H05RN-F 2X0,75 - RUBBER-SHEATED CABLE | M0008287_3500022
Indoor Outdoor
Oil resistant
CE CPR Class - Eca VDE HAR
fixed installation flexible use
Light and middle rubber-sheathed flexible cables

H05RR-F, H05RN-F

07.01.01

|

Application

H05RR-F: light rubber-sheathed cable for light and medium mechanical requirements. For connecting of electrical hand-held units in household and office. Suitable in dry, humid and wet rooms. Not for permanent outdoor use.

H05RN-F: rubber-sheathed cable for medium mechanical requirements. For connecting of electrical hand-held units in household and office. Suitable in dry, humid, wet rooms and for outdoor use.

Selected item
Item no.: Description:
3500022 H05RN-F 2X0,75 RUBBER-SHEATED CABLE
Variants
Filter
TKD CoreFit offers functional alternatives that cover the core benefits of the original product—often with reduced functionality or simpler design, but at a lower price.
Filter

Filter according to your requirements.

fixed installation flexible use
H05RR-F, H05RN-F 2 X 0,75 3500035
Light and middle rubber-sheathed flexible cables
300/500V, unshielded, HAR, CPR Eca
fixed installation flexible use
H05RR-F, H05RN-F 2 X 1,5 3500039
Light and middle rubber-sheathed flexible cables
300/500V, unshielded, HAR, CPR Eca
fixed installation flexible use
H05RR-F, H05RN-F 2 X 1 3500023
Light and middle rubber-sheathed flexible cables
300/500V, unshielded, HAR, CPR Eca
fixed installation flexible use
H05RR-F, H05RN-F 2 X 1 3500037
Light and middle rubber-sheathed flexible cables
300/500V, unshielded, HAR, CPR Eca
Despite careful pre-evaluation of our alternatives, we ask you to review the selection based on your requirements. Our recommendations include at least equivalent, and in some cases better, properties.
PRODUCT INFO "H05RR-F, H05RN-F "
SPECIAL FEATURES
  • free from lacquer damaging substances and silicone (during production)
REMARKS
  • RoHS compliant
  • Compliant with the 2014/35/EU Directive (''Low Voltage Directive'') CE
  • Special versions, other dimensions, cross-sections, wire and sheath colors are available on request.
PRODUCT DETAILS
DESIGN
Conductor material bare or tinned copper strand
Conductor class acc. to DIN VDE 0295 class 5 and IEC 60228 cl. 5
Core insulation rubber compound
Core identification acc. to DIN VDE 0293-308 coloured with or without GNYE
Stranding cores stranded in layers
Outer sheath material special rubber-compound
Sheath colour black
ELECTRICAL PROPERTIES
Rated voltage AC IEC Uo/U: 300/500 V
Testing voltage 2 kV
Current carrying capacity acc. to DIN VDE, see Technical Guidelines
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed acc. to DIN VDE 0298 part 3
Min. bending radius moved acc. to DIN VDE 0298 part 3
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C] -25 °C / +60 °C
Operat. temp. moved min/max [°C] -25 °C / +60 °C
Temp. at conductor in operation max [°C] +60 °C