FLAME-JZ-CH FRNC Cca 25G1 - 300/500 V, GREY RAL 7001 | M0004000_1005809
Halogen-free control cables

FLAME-JZ/OZ-CH FRNC - Cca oder B2ca

01.03.02.02

|

Application
shielded halogen-free and environmentally power, control and connecting cable in electrical facilities, in fire vulnerable areas and facilities with high concentration of people and property values, for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry and humid rooms. Outdoor use only with UV-protection, no laying underground.
Selected item
Item no.: Description:
1005809 FLAME-JZ-CH FRNC Cca 25G1 300/500 V, GREY RAL 7001
Article Name
Variants
Item no. Dimension Outer-Ø [mm] nom. Cu Index [kg/km] Weight [kg/1.000]
"FLAME-JZ/OZ-CH FRNC - Cca oder B2ca "
SPECIAL FEATURES
  • FRNC (Flame Retardant, Non Corrosive)
  • LSF 0H ( Low smoke in fume, zero halogen)
  • improved behaviour in case of fire (acc. to IEC 60332-3-25 Cat. A)
  • recommended for EMC-applications
REMARKS
  • RoHS compliant
  • compliant with 2014/35/EU Directive (''Low Voltage Directive'') CE 
  • LABS-free/silicone-free (during production) 
DESIGN
Conductor material bare copper strand
Conductor class acc. to IEC 60228 cl. 5
Core insulation special halogen-free compound
Core identification acc. to DIN VDE 0293 black cores with white numerals; G = GNYE
Stranding stranded in layers
Overall shield copper braid tinned; coverage approx. 85 %
Outer sheath material special halogen-free compound
Sheath colour grey, RAL 7001
ELECTRICAL PROPERTIES
Rated voltage AC IEC Uo/U: 300/500 V
Testing voltage 3 kV
Conductor resistance acc. to IEC 60228 cl. 5
Insulation resistance min. 20 MΩ x km
Current carrying capacity acc. to DIN VDE, see technical Guidelines
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed 6 x d
Min. bending radius moved 15 x d
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C] -40 °C / +70 °C
Operat. temp. moved min/max [°C] -15 °C / +70 °C
PROPERTIES IN CASE OF FIRE
Halogen-free acc. to IEC 60754-1
Smoke density acc. to IEC 61034-2
Corrodibility acc. to IEC 60754-2
Burning behavior halogen-free and flame-retardant acc. to IEC 60332-1-2 and IEC 60332-3-24 Cat. C resp. IEC 60332-3-25 Cat. A
CPR - fire class B2ca

Please enter a valid email address.
Please enter a valid question.
Fields marked with * are mandatory.
KAWEFLEX® Allround 7110 SK-PVC UL/CSA 04.11.05
Control cables for use in drag chains
for increased requirements, 300/500V, unshielded, UL/CSA
Item count 47
KAWEFLEX® Allround 7720 SK-TP-C-PUR UL/CSA 04.15.10
Electronic cables for use in drag chains
for high requirements, 300V, shielded, halogen-free, UL/CSA
Item count 24
NYCY 0,6/1kV 09.07.02
Power Cables
0,6/1kV, shielded, UV-resistant, direct burial, VDE, CPR Eca
Item count 47
AUTO B - RADOX® Databus 155S RW/REMS 20.10.04
BUS data cables for automotive
Item count 1