Indoor
Shielded
CE CSA
fixed installation flexible use
Approved electronic and data cables

DATATRONIC®-CY UL/CSA

02.04.05

|

Application

UL/CSA approved data transmission cable, control and connecting cable predominantly for transmission of analog and digital signals in process controlled facilities in measurement and control technology for lossless data and signal transmission. For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only with UV-protection, no laying underground.

Selected item
Item no.: Description:
0500083 DATATRONIC-CY (TP) UL 2560/CSA 13X2XAWG28/7 (0,09 QMM) DIN47100, GREY RAL 7032
Variants
Filter
There are currently no available alternative products.
PRODUCT INFO "DATATRONIC®-CY UL/CSA "
SPECIAL FEATURES
  • twisted pairs
  • largely resistant to acids, bases and specified types of oil
  • LABS-/silicone-free (during production)
  • recommended for EMC-applications
  • adapted to connectors according DIN 41612 resp. VG Norm95324 also D-Sub according MIL-C24308 and capable for soldering, crimp and cut-and-clamp
REMARKS
  • RoHS compliant
  • Compliant with the 2014/35/EU Directive (''Low Voltage Directive'') CE
  • Special versions, other dimensions, cross-sections, wire and sheath colors are available on request.
PRODUCT DETAILS
DESIGN
Conductor material copper strand tinned
Conductor class 7 wired; AWG28/7 = 7 x 0,13 mm (0,09 mm²); AWG24/7 = 7 x 0,203 mm (0,22 mm²)
Core insulation AWG24: special SR-PVC (Semi-Rigid-PVC); AWG28: special-PVC
Core identification acc. to DIN 47100 different colours, with repetition from 23rd pair
Stranding 2 cores twisted to a pair; pairs stranded in layers
Overall shield copper braid tinned; coverage approx. 85% with subjacent tinned drain wire
Outer sheath material PVC
Sheath colour grey, RAL 7032
ELECTRICAL PROPERTIES
Rated voltage AC IEC AWG28/7 = 250 V acc. to VDE; 30 V acc. to UL style 2560; AWG24/7 = 300 V acc. to VDE and UL style 2464
Testing voltage 1.2 kV
Conductor resistance on AWG28/7 < 250 Ω/km; on AWG24/7 < 130 Ω/km
Insulation resistance min. 200 MΩ x km
Current carrying capacity acc. to DIN VDE, s. Techn. Guidelines
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed up to 12 mm Ø 5 x d; up to 20 mm Ø 7,5 x d; > 20 mm Ø 10 x d
Min. bending radius moved up to 12 mm Ø 10 x d; up to 20 mm Ø 15 x d; > 20 mm Ø 20 x d
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C] -30 °C / +80 °C; acc. to UL -5 °C / +60 °C
Operat. temp. moved min/max [°C] -5 °C / +70 °C; acc. to UL -5 °C / +60 °C
STANDARDS & APPROVALS
Standard UL style 2560 (AWG28/7) resp. UL style 2464 (AWG 24/7)
Approvals UL/CSA: AWG28/7: 60 °C - 30 V; AWG24/7: 60 °C - 300 V