BUS | FIELDBUS cables for industrial & process automation
CAN BUS - ControlerAreaNetwork 120 Ohm - HF UL/CSA -high flexible -
03.10.03.02
|
Application
as fieldbus cables for CAN (Controller Area Network) systems, in the field of factory automation, foryle="line-height:1.6em">high flexible applications (e.g. power chains, gantry robots, pick&place units, conveyors, machine tools, automated production systems, etc.) This bussystem has its origins in the automotive sector and has established itself in the field of production automation. Standard acc. to CAN Spec.: ISO 11898
as fieldbus cables for CAN (Controller Area Network) systems, in the field of factory automation, foryle="line-height:1.6em">high flexible applications (e.g. power chains, gantry robots, pick&place units, conveyors, machine tools, automated production systems, etc.) This bussystem has its origins in the automotive sector and has established itself in the field of production automation. Standard acc. to CAN Spec.: ISO 11898
Selected item
Item no.:
Description:
2003674
CAN BUS SK-C-PUR FRNC UL/CSA
1X2XAWG24 (0,25 mm²)
VIOLET, cULus CMX
Variants
There are currently no available alternative products.
PRODUCT INFO
"CAN BUS - ControlerAreaNetwork 120 Ohm - HF UL/CSA -high flexible -"
SPECIAL FEATURES
- low adhesion
- largely resistant to grease, coolant fluids and lubricants
- oil-resistant: acc. to DIN EN 60811-2-1
- UV-resistant
- EMC compliant shielding
- max. transmission rate: 1 Mbit/s at 40m segment length
- max. cable lengths for a bus segment depending on the cross section 0- 40 m AWG24, AWG22 | 40-300 m AWG22, AWG20 | 300-600 m AWG20 | 600-1.000 m AWG19
REMARKS
- RoHS-compliant
- DESINA-compliant (violet)
- Compliant with the 2014/35/EU Directive (''Low Voltage Directive'') CE
- LABS/silicon-free (during production)
- FRNC: Flame Retardant Non Corrosive, halogen-free
PRODUCT DETAILS
DESIGN
| Conductor material | copper conductor blank |
|---|---|
| Conductor class | super fine wire acc. to IEC 60228 cl. 6 |
| Core insulation | foamed PE/PP |
| Core identification | acc. to DIN 47100 |
| Stranding | cores twisted to pairs |
| Overall shield | copper braid tinned |
| Outer sheath material | PUR |
| Sheath colour | violet RAL 4001 (VT) |
ELECTRICAL PROPERTIES
| Rated voltage AC IEC | 250 V (not for high voltage purposes) |
|---|---|
| Testing voltage | 1,5 kV |
| Loop resistance | max. 175,2 Ω/km - AWG 24, max. 110,8 Ω/km - AWG 22; max. 68,8 Ω/km - AWG 20; max 55,0 Ω/km - AWG 19 |
| Capacity | nom. 40 nF/km |
| Characteristic impedance | 120 Ω +/- 12 Ω |
MECHANICAL & DYNAMIC PROPERTIES
| Min. bending radius fixed | 5 x d |
|---|---|
| Min. bending radius moved | 7,5 x d < 3mTL* | 15 x d ≥ 3mTL* |
| Traverse length (m) - drag chain | max. 10 m |
| Traverse speed (m/s) - drag chain | self-supporting: 4 m/s |
| Acceleration (m/s²) - drag chain | max. 5 m/s² |
THERMAL PROPERTIES
| Operat. temp. fixed min./max. [°C] | -40 °C / +80 °C |
|---|---|
| Operat. temp. moved min/max [°C] | -30°C / +70°C |
PROPERTIES IN CASE OF FIRE
| Halogen-free | acc. to IEC 60754-1 (FRNC Typen) |
|---|---|
| Burning behavior | flame-retardant acc. to IEC 60332-1-2, VW-1 |