BUS | FIELDBUS cables for industrial & process automation
ASi-BUS Aktor Sensor Interface - HF UL/CSA -high flexible -
03.10.06.02
|
as fieldbus cables for ASi (Actuator Sensor Interface) systems, in the field of factory automation, for connecting devices to the lowest field level (sensors, actuators), for high flexible applications (e.g. power chains, gantry robots, pick&place units, conveyors, machine tools, automated production systems, etc.). Data & energy are transmitted via an unscreened, geometrically coded two-core flat cable. Standard acc. to EN 50295 / IEC 62026
BUS | FIELDBUS cables for industrial & process automation
SPECIAL FEATURES
- low adhesion
- special geometry prevents incorrect contacting (reverse polarity protection)
- simple & quick installation without tools (piercing technology)
- oil resistant: acc. to DIN EN 60811-2-1
- UV-resistant
REMARKS
- RoHS compliant
- Compliant with the 2014/35/EU Directive (''Low Voltage Directive'') CE
- LABS/silicone-free (during production)
- FRNC: Flame Retardant Non Corrosive, halogen-free
- LD - Long Distance.
PRODUCT DETAILS
DESIGN
| Conductor material | copper strand tinned |
|---|---|
| Conductor class | super fine wire, acc. to IEC 60228 cl. 6 |
| Core insulation | TPE |
| Core identification | blue, brown |
| Outer sheath material | PUR |
| Sheath colour | yellow RAL 1023 (YE) or black RAL 9005 (BK) |
ELECTRICAL PROPERTIES
| Rated voltage AC IEC | 300 V (not for high voltage purposes) |
|---|---|
| Testing voltage | 2 kV |
| Conductor resistance | 13,7 Ω/km - 1,5mm²; 8,21 Ω/km 2,5 mm² |
| Capacity | nom. 80 nF/km |
MECHANICAL & DYNAMIC PROPERTIES
| Min. bending radius fixed | 12 mm |
|---|---|
| Min. bending radius moved | 60 mm |
| Traverse length (m) - drag chain | max. 5 m |
| Acceleration (m/s²) - drag chain | max. 3 m/s² |
THERMAL PROPERTIES
| Operat. temp. fixed min./max. [°C] | -40°C / +80°C |
|---|---|
| Operat. temp. moved min/max [°C] | -30°C / +70°C |